Put the Control Panel into learning mode. If installing multiple panels only one panel should be in learning mode at a time.
Reset the sensor before attempting to pair it. (See instructions below.)
Hold tamper and slide the battery tray into the body. Hold tamper for 2 seconds.
The red LED lights for two seconds, then the detector enters pairing mode.
The red LED flashes three times every five seconds until the control panel discovers the detector. The control panel will beep once.
IMPORTANT: Move the sensor around or wave your hand in front of the sensor. The control panel will beep a second time.
The blue tile in WMI will show the label IR within 60 seconds. If the tile doesn't show IR, exit learning mode in WMI and restart learning. Repeat the above steps.
Click on the blue tile labelled IR in WMI to complete pairing.
After the device is learnt-in, put the Control Panel/Hub into Walk Test mode. Hold the sensor in the desired location, and press the Test button to confirm this location is within the signal range of the Control Panel/Hub.
Remove the back panel to get access to the battery tray.
Remove the battery tray.
Hold the tamper switch while you reinsert the battery tray, the LED will be solid red while the tamper is held in.
Release the tamper within 4 seconds.
The sensor is now factory reset.
When resetting the Bosch PIR, the technician should wait at least 60 seconds before attempting to pair the PIR again. This is because the reset process takes a minimum of 50 seconds to fully complete.
This process may take 3 or 4 attempts in some cases. Please ensure that the PIR is unpaired correctly before attempting to re-pair.